hp-Double unit HSPD series
This hp-Oil supply is for fire places with heating oil EL to DIN/EN 12514-1.
Details and applications
Accessories:
16. Spill protection according VbF with WHG permisson
Model | Discharge l/h |
ave. Extraction quantity l/h |
Motor power | Item No. | max. burner connections |
GWeight Kg approx. |
||
Alternating current |
Rotary current | HSPD | additional burner connections |
|||||
HSPD 30 – 6042 | 80 | 50 | 0,18 kW | – | 430104 | 430200 | 4 | 8 |
HSPD 60 – 6044 | 160 | 120 | 0,18 kW | – | 430108 | 430200 | 4 | 0 |
HSPD 200 – 6045 | 300 | 200 | 0,18 kW | – | 430114 | 430201 | 4 | 2 |
HSPD 200 – 6047 | 600 | 400 | 0,18 kW | – | 430124 | 430201 | 4 | 2 |
HSPD 700 BHP | 1000 | 700 | – | 0,75 kW | 430130 | 430202 | 5 | 185 |
HSPD 700 BHM | 1500 | 1000 | – | 0,75 kW | 430138 | 430202 | 5 | 185 |
HSPD 700 BHG | 2000 | 1500 | – | 0,75 kW | 430142 | 430202 | 5 | 185 |
HSPD 1500 BHGP | 3000 | 2200 | – | 1,10 kW | 430148 | 430210 | 5 | 230 |
Leakage detector in plug-in casing Type LMS for 230 V (for description see page 83). | ||||||||
Leakage detector in control system integrated Type LMP for 230/400 V | ||||||||
From HSPD 30, additional spill protection to VbF or WHG permitted | 720713 | |||||||
For further dimensions see page 52. |
Unit | Modelp | Pump | Motor | Connections | Tank data | ||||||||||||||||
Discharge power pump l/h |
Ave. extraction quantit 1) [l/h] |
W-alternating current ~230 V D-rotary current 230/400 V |
Suction port for pipe Ø |
Consumer connection for pipe Ø |
Air discharge port connection |
Model | Capacity (litres) |
First fill (litres) |
Length (mm) L1 |
Width (mm) B1 |
Height (mm) H1 |
Oil pan L x B x H |
|||||||||
HSPE 30 – | 6042 | 80 | 50 | W-0,18 kW | 12 | 12 | G ¾” | NG 30 | 25 | 4 | 500 | 350 | 310 | 600 x 400 x 150 | |||||||
HSPE 60 – | 6044 | 160 | 120 | W-0,18 kW | 15 | 12 | G ¾” | NG 30 | 25 | 4 | 500 | 350 | 310 | 600 x 400 x 150 | |||||||
HSPE 200 – | 6045 | 300 | 200 | W-0,18 kW | 18 | 15 | G 1” | NG 70 | 63 | 22 | 610 | 470 | 370 | 800 x 600 x 150 | |||||||
HSPE 200 – | 6047 | 600 | 400 | W-0,18 kW | 18 | 15 | G 1” | NG 70 | 63 | 22 | 610 | 470 | 370 | 800 x 600 x 150 | |||||||
HSPE 700 – | BHP | 1000 | 700 | D-0,75 kW | 28 | 22 | G 1¼” | E 160 | 160 | 40 | 810 | 570 | 560 | 1160 x 745 x 150 | |||||||
HSPE 700 – | BHM | 1500 | 1000 | D-0,75 kW | 28 | 22 | G 1¼” | E 160 | 160 | 40 | 810 | 570 | 560 | 1160 x 745 x 150 | |||||||
HSPE 700 – | BHG | 2000 | 1500 | D-0,75 kW | 28 | 22 | G 1¼” | E 160 | 160 | 40 | 810 | 570 | 560 | 1160 x 745 x 150 | |||||||
HSPE 1500 – | BHGP | 3000 | 2200 | D-1,1 kW | 42 | 28 | G 1½” | E 250 | 280 | 40 | 1010 | 700 | 580 | 1300 x 1100 x 150 | |||||||
HSPD 30 – | 6042 | 80 | 50 | W-0,18 kW | 12 | 12 | G ¾” | NG 30 | 25 | 4 | 500 | 350 | 310 | 600 x 400 x 150 | |||||||
HSPD 60 – | 6044 | 160 | 120 | W-0,18 kW | 15 | 12 | G ¾” | NG 30 | 25 | 4 | 500 | 350 | 310 | 600 x 400 x 150 | |||||||
HSPD 200 – | 6045 | 300 | 200 | W-0,18 kW | 18 | 15 | G 1” | NG 70 | 63 | 22 | 610 | 470 | 370 | 800 x 600 x 150 | |||||||
HSPD 200 – | 6047 | 600 | 400 | W-0,18 kW | 18 | 15 | G 1” | NG 70 | 63 | 22 | 610 | 470 | 370 | 800 x 600 x 150 | |||||||
HSPD 700 – | BHP | 1000 | 700 | D-0,75 kW | 28 | 22 | G 1¼” | E 160 | 160 | 40 | 810 | 570 | 560 | 1160 x 745 x 150 | |||||||
HSPD 700 – | BHM | 1500 | 1000 | D-0,75 kW | 28 | 22 | G 1¼” | E 160 | 160 | 40 | 810 | 570 | 560 | 1160 x 745 x 150 | |||||||
HSPD 700 – | BHG | 2000 | 1500 | D-0,75 kW | 28 | 22 | G 1¼” | E 160 | 160 | 40 | 810 | 570 | 560 | 1160 x 745 x 150 | |||||||
HSPD 1500 – | BHGP | 3000 | 2200 | D-1,1 kW | 42 | 28 | G 1½” | E 250 | 280 | 40 | 1010 | 700 | 580 | 1300 x 1100 x 150 |
Unit | Model | Electrical equipment | Solenoid valves option | ||||||||||||||||||
Control system with leakage detector (Model; item no.:) |
Level measurement |
Temperature monitoring |
Spill protection |
Optional spill protection to WHG |
Solenoid valve to DIN/EN (anti-lift valve) 230 V, 50 Hz |
Piston solenoid valve (TÜV and DIN tested) [-1 to 16 bar] |
|||||||||||||||
HSPE 30 – | 6042 | µCON I alternating current 0720075-01 |
NIVOCAP (capacitive level sensor) Item no.: 0710176 |
Temperature switch KTY81-110 / 50°C Item No.: 0720636 |
Level switch LS01 BV 14575 Item No.: 0720729 |
Overflow protection permitted to VbF and 63 WHG “Liquifant FTL-31” Item No.: 0720713 -2 |
G ⅜” – DN 10 (0820250) |
“G ⅜“ (0820256) |
|||||||||||||
HSPE 60 – | 6044 | G ½” – DN 12 (0820342) |
MK 10 G ½” (0820257) |
||||||||||||||||||
HSPE 200 – | 6045 | ||||||||||||||||||||
HSPE 200 – | 6047 | ||||||||||||||||||||
HSPE 700 – | BHP | µCON I rotary current 0720076-01 |
G 1″ – DN 25 (0820344) |
MK 15 G 1″ (0820259) |
|||||||||||||||||
HSPE 700 – | BHM | ||||||||||||||||||||
HSPE 700 – | BHG | ||||||||||||||||||||
HSPE 1500 – | BHGP | G 1¼” – DN 25 (0820345) |
MK 20 G 1¼” (0820260) |
||||||||||||||||||
HSPD 30 – | 6042 | µCON III alternating current 0710050-11 |
NIVOCAP (capacitive level sensor) Item no.:0710176 |
Temperature switch KTY81-110 / 50°C Item No.: 0720636 |
Level switch LS01 BV 14575 Item No.: 0720729 |
Overflow protection permitted to VbF and 63 WHG “Liquifant FTL-31” Item No.: 0720713 -2 |
G ⅜“ – DN 10 (0820250) |
G ⅜” (0820256) |
|||||||||||||
HSPD 60 – | 6044 | G ½” – DN 12 (0820342) |
MK 10 G ½” (0820257) |
||||||||||||||||||
HSPD 200 – | 6045 | ||||||||||||||||||||
HSPD 200 – | 6047 | ||||||||||||||||||||
HSPD 700 – | BHP | µCON III rotary current 0710070-11 |
G 1″ – DN 25 (0820344) |
MK 15 G 1″ (0820259) |
|||||||||||||||||
HSPD 700 – | BHM | ||||||||||||||||||||
HSPD 700 – | BHG | ||||||||||||||||||||
HSPD 1500 – | BHGP | G 1¼“ – DN 25 (0820345) |
MK 20 G 1¼” (0820260) |
HSP30-200
HSP700-1500
Subject to technical alterations.
1) max. discharge power in l/h = max. pump suction flow! Measured for heating oil EL
The average extraction quantity in l/h depending suction height, suction length, pipe diameter is produced from the empirically-determined performance tables.
hp-Suction units Series HSP Based on empirical determination with heating oil EL at 20 °C.
These performance curves are based on tests with optimum pipe flow and may only be considered as guidelines. Not all usage cases can be derived from them. Copying, duplication or forwarding to third parties requires our written permission.
Need additional infos? Please contact us