Motor Pump Group SMG – for industrial pumps of the series NV with integrated overflow valve and bypass

For Single units with 1400 RPM with hp-Industrial pumps. The pump connections are marked as follows:

A = Suction connection
S = Delivery connection
R = Bypass connection

The pumps are designed in the standard version with direction of rotation I = counterclockwise (viewed from the pump shaft). The position of the pump connections depends on direction of rotation.

Technical Data:

  • Suitable for use with hydraulic oils, lubricating oils, all heating oils, coal tar oils, kerosenes and many other self-lubricating fluids
  • The motor powers are applicablefor fluids with a viscosity up to 80 cSt.
  • From 80 to 150 cSt. the motor must be designed by one power stage – construction size – larger
  • Standard design:
    • Units up to 9 bar: Pressure stage 2 = 2 to 9 bar
    • Units up to 40 bar: Pressure stage 4 = 15 to 40 bar
    • Other pressure stages according to model key, please specify with order

Technical selection tables for SMG single units with 1400 rpm industrial pumps series NV

Series size Pump model Discharge at 1400 RPM Motor power Connections
1) *
H1 heating
Watt
Gear rotor / shaft

Ø

Item No.
at 0 – 9 bar at 30 bar
SMG 1701 NVBRP 45 l/h 0,18 kW G 3/8“ 100 25/12 370001 f

for max. pressure
designed from 9 bar

to DIN/EN 12514-1
on max. pressure
limited from 6 bar
and set

SMG 1702 NVBRM 80 l/h 0,18 kW G 3/8“ 100 25/12 370002
SMG 1703 NVBRG 120 l/h 0,18 kW G 3/8“ 100 25/12 370003
SMG 1704 NVBRF 160 l/h 0,18 kW G 3/8“ 100 25/12 370004
SMG 1705 NVBGRP 300 l/h 0,18 kW G 1/2“ 100 38/12 370005
SMG 1706 NVBGRM 450 l/h 0,37 kW G 1/2“ 100 38/12 370006
SMG 1707 NVBGRG 600 l/h 0,37 kW G 1/2“ 100 38/12 370007
SMG 1708 NVBHRP 1000 l/h 0,75 kW G 3/4“ 160 56/18 370008
SMG 1709 NVBHRM 1500 l/h 0,75 kW G 3/4“ 160 56/18 370009
SMG 1710 NVBHRG 2000 l/h 1,1 kW G 3/4“ 160 56/18 370010
SMG 1721 NVBRP 45 l/h 30 l/h 0,18 kW G 3/8“ 100 25/12 370011 pmax 30 bar
SMG 1722 NVBRM 80 l/h 60 l/h 0,18 kW G 3/8“ 100 25/12 370012
SMG 1723 NVBRG 120 l/h 100 l/h 0,18 kW G 3/8“ 100 25/12 370013
SMG 1724 NVBRF 160 l/h 140 l/h 0,37 kW G 3/8“ 100 25/12 370014
SMG 1725 NVBGRP 300 l/h 240 l/h 0,37 kW G 1/2“ 100 38/12 370015
SMG 1726 NVBGRM 450 l/h 390 l/h 0,75 kW G 1/2“ 100 38/12 370016
SMG 1727 NVBGRG 600 l/h 520 l/h 0,75 kW G 1/2“ 100 38/12 370017
SMG 1728 NVBHRP 1000 l/h 700 l/h 1,5 kW G 3/4“ 160 56/18 370018
SMG 1729 NVBHRM 1500 l/h 1200 l/h 2,2 kW G 3/4“ 160 56/18 370019
SMG 1730 NVBHRG 2000 l/h 1700 l/h 3,0 kW G 3/4“ 160 56/18 370020
Series size Pump model Discharge at 1400 RPM Motor power Connections
1) *
H1 heating
Watt
Gear rotor / shaft

Ø

Item No.
at 0 bar at 40 bar
SMG 1962 NVBRM 80 l/h 50 l/h 0,18 kW G 3/8“ 100 25/12 390067 for max. pressure
designed from 40 bar
SMG 1963 NVBRG 120 l/h 80 l/h 0,37 kW G 3/8“ 100 25/12 390068
SMG 1964 NVBRF 160 l/h 120 l/h 0,37 kW G 3/8“ 100 25/12 390069
SMG 1965 NVBGRP 300 l/h 200 l/h 0,75 kW G 1/2“ 100 38/12 390070
SMG 1966 NVBGRM 450 l/h 360 l/h 1,1 kW G 1/2“ 100 38/12 390071
SMG 1967 NVBGRG 600 l/h 480 l/h 1,5 kW G 1/2“ 100 38/12 390072
SMG 1968 NVBHRP 1000 l/h 600 l/h 2,2 kW G 3/4“ 160 56/18 390073
SMG 1969 NVBHRM 1500 l/h 1000 l/h 3 kW G 3/4“ 160 56/18 390074
SMG 1970 NVBHRG 2000 l/h 1400 l/h 4 kW G 3/4“ 160 56/18 390075
Series size Pump model Discharge Motor power Dimensions
regardless of motor for IE-3
a a1 b c e1 f3 g1 h k2 s k k3 k4
SMG 1701 NVBRP 45 l/h 0,18 kW 80 36 100 7 G 3/8“ 32,5 65 63 165 7 345 180 60
SMG 1702 NVBRM 80 l/h 0,18 kW 80 36 100 7 G 3/8“ 32,5 65 63 165 7 345 180 60
SMG 1703 NVBRG 120 l/h 0,18 kW 80 36 100 7 G 3/8“ 32,5 65 63 165 7 345 180 60
SMG 1704 NVBRF 160 l/h 0,18 kW 80 36 100 7 G 3/8“ 32,5 65 63 165 7 345 180 60
SMG 1705 NVBGRP 300 l/h 0,18 kW 80 40 100 7 G 1/2“ 35 70 63 179 7 359 180 60
SMG 1706 NVBGRM 450 l/h 0,37 kW 90 40 112 7 G 1/2“ 35 70 71 186 7 396 210 82
SMG 1707 NVBGRG 600 l/h 0,37 kW 90 40 112 7 G 1/2“ 35 70 71 186 7 396 210 82
SMG 1708 NVBHRP 1000 l/h 0,75 kW 100 49 125 8 G 3/4“ 50 100 80 268 9,5 555 287 137
SMG 1709 NVBHRM 1500 l/h 0,75 kW 100 49 125 8 G 3/4“ 50 100 80 268 9,5 555 287 137
SMG 1710 NVBHRG 2000 l/h 1,1 kW 100 49 140 10 G 3/4“ 50 100 90 278 10 615 337 181
SMG 1721 NVBRP 45 l/h 0,18 kW 80 36 100 7 G 3/8“ 32,5 65 63 165 7 345 180 60
SMG 1722 NVBRM 80 l/h 0,18 kW 80 36 100 7 G 3/8“ 32,5 65 63 165 7 345 180 60
SMG 1723 NVBRG 120 l/h 0,18 kW 80 36 100 7 G 3/8“ 32,5 65 63 165 7 345 180 60
SMG 1724 NVBRF 160 l/h 0,37 kW 90 36 112 7 G 3/8“ 32,5 65 71 172 7 382 210 82
SMG 1725 NVBGRP 300 l/h 0,37 kW 90 40 112 7 G 1/2“ 35 70 71 186 7 396 210 82
SMG 1726 NVBGRM 450 l/h 0,75 kW 100 40 125 8 G 1/2“ 35 70 80 206 9,5 493 287 137
SMG 1727 NVBGRG 600 l/h 0,75 kW 100 40 125 8 G 1/2“ 35 70 80 206 9,5 493 287 137
SMG 1728 NVBHRP 1000 l/h 1,5 kW 125 49 140 10 G 3/4“ 50 100 90 278 10 615 337 156
SMG 1729 NVBHRM 1500 l/h 2,2 kW 140 49 160 12 G 3/4“ 50 100 100 288 12 652 364 160
SMG 1730 NVBHRG 2000 l/h 3,0 kW 140 49 160 12 G 3/4“ 50 100 100 288 12 608 320 117
SMG 1962 NVBRM 80 l/h 0,18 kW 80 36 100 7 G 3/8“ 65 67 63 165 7 345 180 60
SMG 1963 NVBRG 120 l/h 0,37kW 90 36 112 7 G 3/8“ 65 67 71 172 7 382 210 82
SMG 1964 NVBRF 160 l/h 0,37 kW 90 36 112 7 G 3/8“ 65 67 71 172 7 382 210 82
SMG 1965 NVGRP 300 l/h 0,75 kW 100 40 125 8 G 1/2“ 70 75 80 206 9,5 493 287 160
SMG 1966 NVBGRM 450 l/h 1,1 kW 100 40 140 10 G 1/2“ 70 75 90 206 10 543 337 181
SMG 1967 NVBGRG 600 l/h 1,5 kW 125 40 140 10 G 1/2“ 70 75 90 206 10 543 337 156
SMG 1968 NVBHRP 1000 l/h 2,2 kW 140 49 160 12 G 3/4“ 100 105 100 288 12 652 364 160
SMG 1969 NVBHRM 1500 l/h 3,0 kW 140 49 160 12 G 3/4“ 100 105 100 288 12 652 364 160
SMG 1970 NVBHRG 2000 l/h 4,0 kW 140 49 190 12 G 3/4“ 100 105 112 288 12 635 347 137

1) Pipe connections pipe thread DIN ISO 228-1
* To ensure the pump is working properly, the pipes must be scaled according to the principles of fluid dynamics by calculation of line according to the local requirements.
The pump or device connection gives no indication of the relevant size of the pipe

The dimensional specifications of the electric motors vary according to manufacturer, therefore the dimensions of the motor pump units are not binding.

Diagram

Need additional infos? Please contact us

Jochen Twellaar

+49 (0) 721/95618-23

twellaar@hptechnik.com

Joachim Rau

+49(0) 721/95618-25

rau@hptechnik.com